Navigation :
Manual
Input Variables
-
Atomic Orbitals
-
Calculation Modes
-
ClassicalParticles
-
DFTBPlusInterface
-
Execution
-
Hamiltonian
-
Linear Response
-
Math
-
Maxwell
-
MaxwellStates
-
Mesh
-
Output
-
SCF
-
States
-
System
-
Time-Dependent
--
Absorbing Boundaries
--
PhotoElectronSpectrum
--
Propagation
--- ArnoldiOrthogonalization
--- InteractionTiming
--- IonsConstantVelocity
--- IonsTimeDependentDisplacements
--- MaxwellAbsorbingBoundaries
--- MaxwellBoundaryConditions
--- MaxwellTDETRSApprox
--- MaxwellTDIntervalSteps
--- MaxwellTDOperatorMethod
--- MaxwellTDSCFThreshold
--- MoveIons
--- RecalculateGSDuringEvolution
--- TDDynamics
--- TDEnergyUpdateIter
--- TDExponentialMethod
--- TDExpOrder
--- TDIonicTimeScale
--- TDLanczosTol
--- TDMaxSteps
--- TDMaxwellKSRelaxationSteps
--- TDMaxwellTDRelaxationSteps
--- TDPhotonicTimeScale
--- TDPropagationTime
--- TDPropagator
--- TDSCFThreshold
--- TDStepsWithSelfConsistency
--- TDSystemPropagator
--- TDTimeStep
--- TemperatureFunction
--- Thermostat
--- ThermostatMass
--
Response
--
TD Output
-- MaxwellFunctions
-- TDExternalFields
-- TDFreezeDFTUOccupations
-- TDFreezeHXC
-- TDFreezeOrbitals
-- TDFreezeU
-- TDFunctions
-- TDGlobalForce
-- TDScissor
-
Utilities
-
Alphabetic Index
Tutorials
Developers
Releases
MaxwellTDIntervalSteps
MaxwellTDIntervalSteps
Section Time-Dependent::Propagation
Type integer
This variable determines how many intervall steps the Maxwell field propagation
does until it reaches the matter time step. In case that MaxwellTDIntervalSteps is
equal to one, the Maxwell time step is equal to the matter one. The default value is 1.
Source information
maxwell/system_mxll.F90 : 307
call parse_variable ( this % namespace , 'MaxwellTDIntervalSteps' , inter_steps_default , this % tr_mxll % inter_steps )