Match Charged particle vel x (t=10 steps)
Commits >
Commit f1dbe11076ccb3bb542605fe66566061d8720041 >
Run spack_foss-2022a_serial_min >
Input 07-lorentz-force.01-charged_particle_coupled_to_maxwell.inp
Value | Reference | Precision | Status |
-1.999881068548127e-04 | -1.699962300068000e-04 | 1.100000000000000e-04 | PASS |
Command: LINEFIELD(ChargedParticle/td.general/coordinates, -1, 6)