Match Pressure (GPa)

Commits > Commit d3675615d01b7319f97a471d787a8168906684ed > Run spack_foss-2022a_serial_min > Input 30-stress.02-gamma_point.inp
Value Reference Precision Status
1.663734597000000e+01 1.663734593000000e+01 1.540000000000000e-07 PASS
Command: GREPFIELD(static/info, 'Pressure \[GPa\]', 8)
Compare to other runs.