Match Local Magnetic Moment (Ni1)

Commits > Commit 7340c9717a63bb8691685536ab6dd281015dc066 > Run foss_ppc_autotools: [foss2022a-serial] > Input 07-noncollinear.02-acbn0.inp
Value Reference Precision Status
2.886239000000000e+00 2.886218500000000e+00 2.360000000000000e-05 PASS
Command: GREPFIELD(static/info, '1 Ni', 3)
Compare to other runs.