Match By (x= 0,y= 0,z=3.02) [step 400]

Commits > Commit 23cadfdc08b3b148a9c434cb52e4be78ff32991e > Run foss_mpi_omp_autotools: [foss2023a-mpi] > Input 12-tddft-currents-to-maxwell.03-benzene-mxll-td-veloc-gauge.inp
Value Reference Precision Status
-2.958137034434910e-07 -2.958134462431620e-07 8.479999999999999e-12 PASS
Command: LINEFIELD(maxwell/output_iter/td.0000400/b_field-y\.x=0\,y=0, 20, 2)
Compare to other runs.