Match Magnetic Field at loop center

Commits > Commit c9606f298ccf4e57d14167459d26815f7508aa3e > Run foss_cmake: [foss2022a-serial, foss-full] > Input 04-biot_savart.01-gs.inp
Value Reference Precision Status
2.818793802101140e-04 2.813190234613920e-04 2.000000000000000e-06 PASS
Command: LINEFIELD(static/Bind_z.x=0\,z=0, 87, 2)
Compare to other runs.